
Coarse filters
Washable mesh-panel coarse filters in stainless steel, nylon and aluminium for the first filtration stage of air handling units, holding back large dust before finer stages.
Cleanroom and purification equipment, and modular cleanroom packages supplied as complete kits, shipped worldwide from China.
SENPEI supplies cleanroom and purification equipment, and modular cleanroom packages as complete kits. Kits are quoted from catalogue families already on this site, including clean booths and electro-galvanised steel panels. Supply only. Every quotation is tied to a defined configuration, its documents and its packing data.
Product catalogue
Configuration lists, documents and price indications appear as they are confirmed. Families that are still being documented show their supply scope and the inputs needed for a quotation.

Ceiling fan filter units in AC, DC and EC versions, booster and slim-profile variants, group control systems and the grid and blank panels that complete an FFU ceiling.
10 documented families
Coarse, medium, sub-HEPA and HEPA filters in the frame, separator and sealing variants used in cleanroom ceilings, fan filter units and air handling units, plus activated carbon and chemical filters.
16 documented families
Air showers and cargo showers, pass boxes, HEPA terminal housings, filter boxes, laminar flow benches and clean booths for general industrial cleanrooms.
10 documented families
Laminar supply ceilings for operating theatres, leak-proof supply ceilings, HEPA outlets and grilles, medical pass boxes, hospital doors, panels and stainless steel fittings for healthcare cleanrooms.
9 documented families
Decontamination pass boxes and VHP units, airtight and laminar flow pass boxes, bag-in bag-out housings, HEPA exhaust units, weighing booths, laminar flow hoods, isolators and stainless fittings for pharmaceutical and laboratory containment.
12 documented familiesFirst families
These families have their supply scope and quotation requirements published. Parameter tables, configurations and documents follow as they are confirmed.

Washable mesh-panel coarse filters in stainless steel, nylon and aluminium for the first filtration stage of air handling units, holding back large dust before finer stages.

Ceiling fan filter units with conventional AC motors for cleanroom builders who need a lower-cost unit where individual or small-group speed control is enough and filters are replaced during routine maintenance.

First-stage panel and pocket pre-filters in synthetic fibre, washable and high-temperature constructions, for air handling units serving commercial and industrial buildings.

Vaporized hydrogen peroxide equipment in three unit types: fumigation pass boxes for small items, decontamination transfer rooms for large loads, and generators that supply sterilant gas to isolators, pass boxes and small rooms.

Bag and rigid-case medium-efficiency filters (F5–F9 to EN 779) in synthetic fibre, glass fibre, panel and box constructions, for the middle stage of air handling systems.

Pass boxes that disinfect items with intense pulsed xenon ultraviolet light while transferring them between clean and non-clean areas, reaching a high kill rate within minutes instead of the roughly 30 minutes a conventional UV pass box needs.

Ceiling blower filter units with a built-in fan for turbulent and laminar cleanrooms, bought by cleanroom builders who want a self-contained unit that filters and pushes air into the room without a remote air handling unit.

High-medium-efficiency filters with very low initial resistance for ventilation systems with little spare fan pressure, such as hospital diagnostic and treatment rooms.

Ultra-thin fan filter units about half the depth of a standard FFU for equipment-end local filtration in clean plants, bought where ceiling or equipment void space is limited and chemical outgassing must stay low.

Close-pleated sub-HEPA (EPA) panel filters on ultra-fine glass fibre or polypropylene paper, rated 95 % to 99.95 %, for cleanrooms and areas between medium and HEPA stages.

Gas-tight pass boxes with mechanically compressed doors, electromagnetic interlock and optional glove port, used where samples must move between zones without any leakage of hazardous agents.

W-shaped high-airflow sub-HEPA filters for central air conditioning and central ventilation systems, removing 1–5 µm particles at high airflow and low resistance.

Pass-through chambers with a disinfectant basin, used in high-containment laboratories to move small acid- and alkali-resistant items through a liquid disinfection barrier between two rooms.

Fan filter units with a gel-seal filter fixing for high-grade cleanrooms, bought where the seal between filter and casing must block contamination reliably and where single units or bands of units sit above process points.

Separatorless mini-pleat HEPA panels of ultra-fine glass fibre paper with hot-melt pleat spacing, for terminal filtration in electronics, pharmaceutical and hospital cleanrooms.

HEPA panel filters with aluminium foil separators between pleats of ultra-fine glass fibre paper, for terminal filtration where a rigid, corrosion-resistant pack is needed.

Fan filter units in an explosion-proof construction for cleanrooms where flammable solvents, vapours or dusts are handled, bought by pharmaceutical, electronics and food plants that must keep air filtration running in a classified hazardous area.

Separator-style HEPA panels with paperboard separators and polyurethane sealant in galvanised, stainless or aluminium frames, for terminal filtration in cleanrooms.

Self-contained fan filter units for spot supply of filtered air in clean zones, bought to add a local clean-air point quickly or to back up an existing ceiling system in semiconductor, electronics, laboratory and hospital areas.

Central control systems that manage a ceiling of EC fan filter units from one point, bought with EC FFU projects in semiconductor, pharmaceutical and large cleanroom buildings where speed, monitoring and energy use must be managed together.

HEPA supply air outlets with a gel-seal channel that locks the filter frame against the housing knife edge for a leak-tight seal, in top-feed and side-feed versions with an optional regulating damper.

HEPA and ULPA panels on PTFE membrane media for corrosive, high-temperature or copper-and-zinc-free duties where glass fibre paper is not suitable.

Personnel air showers with HEPA-filtered air jetted from nozzles on two sides, used at cleanroom entrances to remove dust from clothing before entry; the buyer's contractor positions and connects the cabin on site.

Central control systems that manage a ceiling of AC fan filter units from one point, bought with AC FFU projects in semiconductor, pharmaceutical and large cleanroom buildings where many units must run and be monitored together.

Personnel air showers that add top nozzles to the two side walls so filtered air blows from three directions, for entries where a more thorough dust removal is required; installed and connected by the buyer's contractor.

Negative-pressure booths for weighing powder materials: a fan pulls air through primary, medium-efficiency and HEPA stages over the work zone, containing the powder and protecting the operator and the room.

Modular aluminium ceiling grid systems that carry FFUs, blank panels, lights and duct ends in a cleanroom ceiling, bought by cleanroom builders who want a demountable, reusable grid that can be cut on site and reconfigured later.

HEPA panels with an integral knife-edge frame that pushes into a gel-filled sealing channel, for terminal positions where a gasket seal cannot guarantee tightness.

Close-out panels that seal unused FFU positions in a cleanroom ceiling grid, bought with FFU ceilings to keep unfiltered air out of the room, keep airflow even across the grid and leave a flat, cleanable ceiling plane.

Mini-pleat HEPA panels with a gel potting groove around the flange, sealing against a knife-edge frame for terminal positions in industrial and biological cleanrooms.

Rigid or flexible containment isolators that separate the work zone from the room with a physical barrier and controlled airflow: aseptic units for sterile operations, cell therapy units with integrated equipment, and negative-pressure units for potent or infectious products.

Box-type HEPA filters with mini-pleat packs arranged in a V formation, giving high airflow capacity and low structural resistance in air handling units.

HEPA panels rated for continuous service at 250–280 °C or up to 400 °C, with stainless frames, aluminium foil separators and high-temperature sealant for ovens and hot process air.

Mobile vertical-laminar-flow units (sampling carts) that bring a local HEPA-filtered clean zone to the sampling or transfer point for raw and auxiliary materials in pharmaceutical production.

Panel, box and W-type activated carbon filters that remove odours and gaseous contaminants by adsorption, for make-up air and recirculation in industrial ventilation.

Low-leakage airtight dampers for ventilation ducts in containment facilities, closing with a gas-tight seal so rooms can be isolated for decontamination and zero-leakage duty at a specified pressure difference.

Cargo air showers with rapid roll-up doors for high-frequency goods transfer into cleanrooms; door speed, curtain colour and control mode are fixed per configuration, and the buyer's contractor handles positioning and power on site.

Panel, box and FFU chemical filters with adsorbent media for removing specific gaseous contaminants from process air, cleanrooms and fan filter units.

Mist showers that remove active or toxic dust adhered to cleanroom garments with a fine water mist before personnel leave a controlled area, installed between clean and non-clean zones.

Cargo air showers with automatic sliding doors for logistics corridors serving semiconductor, pharmaceutical and food plants; door sensing and the shower cycle are automatic, and the buyer's contractor positions and connects the unit on site.

Forced full-body shower units installed between contaminated and semi-contaminated zones, where personnel and garments are decontaminated with a dosed disinfectant spray before leaving the controlled area.

Terminal HEPA filter housings for cleanroom ceiling grids, in top-adjustable, replaceable-media and disposable integrated versions; the housing, filter class and ceiling interface are fixed per configuration, and duct connection is done by the installer.

Site furniture and fittings in 304 or 316 stainless steel for pharmaceutical plants and laboratories: work tables, trolleys, racks, sinks, wardrobes and shoe cabinets, made to the dimensions of the room.

Standard HEPA supply outlets (terminal filter boxes with plenum and diffuser plate) for class 1000 to 100000 air-conditioning systems, sized by box, filter face, airflow and duct flange; installed in the ceiling by the buyer's contractor.

Fresh-air and exhaust filter cabinets for ventilation and make-up air: fresh-air cabinets, medium-efficiency exhaust boxes, activated-carbon adsorption boxes and multi-stage air filter boxes, sized by airflow and filter combination; connected to ductwork by the installer.

Fan-powered chemical filtration units with a sealed plenum and slide-out filter modules, configured per project with primary, medium, HEPA, activated-carbon or chemical filter stages; duct connection and commissioning are done by the installer.

Automatic roll-type air filters for pre-filtration of ventilation and air-conditioning intakes, in standard, self-cleaning, explosion-proof and duct-type versions; the roll of media advances automatically on pressure-difference signal, and the frame size is fixed per configuration.

Open horizontal laminar flow clean benches that wash the work zone with filtered air flowing from the rear towards the operator, for processes harmless to the operator; specified by work zone size and placed by the buyer.

Ceiling-mounted laminar supply units for operating theatres, delivering HEPA-filtered air at a steady face velocity over the operating zone, sized by theatre type and ceiling opening.

Supply ceilings for clean operating theatres with a leak-protection layer below the filter bank, factory-made modules assembled on site, and filter replacement from above the ceiling without entering the protected room.

Terminal HEPA supply outlets with a mesh diffuser face for cleanrooms, combining plenum box, final filter and diffuser in one unit for new builds and retrofits.

Medium- and high-efficiency terminal grilles for cleanroom return and exhaust duct connections, sized and filtered per the room cleanliness class.

Low-initial-resistance medium/high-efficiency filter units for fan-coil and air-handling applications in healthcare rooms, in casing sizes from 400 to 1600 m3/h.

Electrostatic air filtration units in five mountings — insert cell, duct section, air-handling-unit section, diffuser outlet and standalone — with washable collection cells.

Wall-mounted transfer chambers with interlocked doors and a UV germicidal lamp, for moving sterile items between hospital rooms of different cleanliness class.

Electro-galvanised steel (electrolytic sheet) wall panels for operating theatres and cleanrooms, factory cut and folded, assembled on site with services routed in the wall cavity.

Stainless steel furniture and fittings for operating theatres and ancillary rooms — cabinets, sinks, workstations, fume cupboards and electrical/gas boxes — made to order against the room layout.
How a quotation works
Product family, the specifications you already have or the fact that they are still open, quantity, destination country and who will install on site.
Dimensions, electrical supply, filter grade, control and materials are checked against fixed configurations. Open points are listed instead of assumed.
Price per configuration, delivery basis, packing data per unit, lead time, payment terms, warranty scope and the documents that ship with the goods.
Pre-shipment inspection records for the quoted configuration, packing as stated, shipping documents, and spare parts if they were included in the order.
Who we supply
We quote to organisations that have, or contract, the people who unload, install, connect and test cleanroom equipment. Installation abroad is not part of our supply.
You put the equipment into drawings, schedules and acceptance documents. You get configuration codes, specification sheets and packing data you can carry into the project file.
You plan replacement batches and install on site. You get matched dimensions, sealing details, batch documentation and consistent packing.
You buy against a known part or a clear technical requirement and install with your own team. You get the same documents and spare parts, quoted as fixed configurations.
Specification guides
The parameters a buyer confirms before a fan filter unit can be quoted as a fixed configuration, and why each one changes the unit.
How to confirm that a replacement HEPA panel filter will fit and perform in the housing or fan filter unit already installed.
Request a quotation
A quotable request names the product family, the key specifications or the fact that they are still open, the quantity, the destination and who will install on site.